Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13641838
| No.13641838
- Product Categories
- Steam Boiler
- Electric Steam Generator
- Gas-fired steam generator
- Air heater
- Heat Pump Water Heater
- Biomass steam generator
- Friendly Links
| Information Name: | Energy saving air source water heater hot water unit |
| Published: | 2015-04-15 |
| Validity: | 30 |
| Specifications: | LWH |
| Quantity: | 9999.00 |
| Price Description: | |
| Detailed Product Description: | Onward air works: Onward air heater, air conditioner heritage core technology to consume some power to compensate, through thermodynamic cycle, made from low grade heat energy (air source) of the surrounding environment, through the compressor to be delivered to a condenser, releasing water tank water heated. It works with the principle of air conditioning and heating when similar, but air conditioning is to draw heat from the indoor air supplied to the natural environment, and the air heater is this part of the heat for domestic hot water heating, the energy efficiency is the electric water heater 4 times, five times the gas water heater, solar water heater is nearly 2 times, and is a new type of high efficiency, energy saving, environmental protection, water heater products. Pay electricity, heat four times the harvest! 1) crown in energy efficient air to water heat unit compressor refrigeration equipment by the National Quality Supervision and Inspection Center, the crown of air source heat pump water heater energy output to energy input ratio that energy efficiency (COP) is generally 2 to 6 with an average of 3 or more can be reached, and the effectiveness of the ordinary electric water boilers ratio (COP) is not greater than 0.95 gas and oil-fired boiler energy efficiency (COP) to only 0.6 to 0.8, and then coal boiler energy efficiency (COP) less Generally only 0.3 to 0.7. 2) stable performance heat pump works properly with the bad environment temperature have a great relationship, parameter setting unit improperly, can cause the unit does not operate normally in the winter, appeared to contribute enough to stop even the frost phenomenon, our company to enhance the industry technical level, establish and improve industry standards as its mission to establish the industry's first state-level heat pump water heater intelligent simulation specialized laboratories bad environment can simulate a bad environment -15 ℃ working conditions between -45 and accurate determination of the water supply unit volume, heat capacity and function of technical data, conduct original design products, while assessing the stability of product quality and operation. Accurate experimental ensure that product design is more reasonable, more secure and stable, more worry-free. Each product in the crown have been tested -10 ℃ ambient conditions. Stable performance in the crown of air source heat pump water heaters, is the use of customer protection. 3) a safe and effective way to protect the heating is completely different from conventional electric heating, to eliminate the conventional electric heating leakage fundamentally, dry and other security risks; heat pump water heater does not require any fuel does not require any fuel pipelines, no fuel leak fire, and other fire safety hazards: multiple protection features designed to determine the safe operation of the unit. Including high and low voltage protection systems, compressor delay start protection. 4)? Green economy no waste water, waste, waste heat emissions, will not produce any air pollution and bad environment. Units get a lot of free heat from the air, every 1 kWh of electricity consumed can output more than 3 to 5 kWh of heat, the thermal efficiency of 350%, you save 65 to 80 percent of electricity. Easy installation: can be installed in the outdoor space, rooftops, balconies, large garage, equipment level, etc., does not require specialized equipment room: On-site installation requires only a three-phase power supply and connect with circulating water tank. 5) operating costs low heat pump water heater does not require fuel delivery costs and storage fees. Maintenance costs and less heat, heat pump system has only two parts movement, less wear and tear, just a simple routine cleaning and maintenance, and usually does not require any maintenance. Microcomputer automatic control without a full-time manager, saving labor costs. 6) hot water supply system of modular control functions by multiple units constituted modular control, automatic control to adjust the running time and put into operation in the order of each unit, each unit to ensure that the total running time is consistent, the entire hot water supply system efficiency and optimize operation. The full realization of microcomputer control, solve the security problem of system operation, the main control board outside the machine is equipped with an LCD display, real-time display of the host temperature temperature (15 ℃ -60 ℃), the temperature of the heating water temperature (6 ℃ -60 ℃). You can directly check, check the unit's operating condition, encountered during commissioning will automatically display the fault code on the fault display, easy to find reasons; in addition, the same feature set on the line controller, the operation more flexible and convenient; the system has powered down protection, when it comes to a sudden stop or misuse of power shutdown unit power unit control system will automatically record the last mode of operation, to be re-power, the unit automatically continues the previous operating mode, without having to re-set the operating parameters . 7) operation is easy to use unit controlled by a microcomputer to run automatically, according to the water temperature and the user, the automatic start and stop, do not need someone Keeper. Adjustable water temperature and the amount of water depending on the season. Water temperature in the 40 ~ 55 ℃ can be set (set according to the season), regardless of ambient temperature changes, water has always been a constant water temperature by setting and can adjust their own ideal mix temperature without affecting the other dorms and cold water; water can be Demand is set, regardless of the increase in equipment capacity. 8) Automatic defrost unit with anti-cream frosting and automation capabilities to ensure the unit at low bad environmental conditions is stable and reliable performance. 9) General function unit is equipped with automatic control system, with power reverse phase protection, leakage protection, water protection, high and low voltage protection systems, compressor exhaust overheating protection function, the system has fault self-test function, and set up the sound and light alarm, providing LCD controller, suggesting a fault condition. 10) running on each host has a very low noise stringent noise figure design, combined with the use of modern computer simulation technology designed duct system, effectively reduce high frequency noise, the noise does not exceed 65 decibels. 11) all-round protection unit has a full range of protection systems, query parameters, system parameters, query and other functions, safe and reliable, convenient, truly without staff on duty, cost savings. 12) Advantages more energy - energy efficiency up to 400% of electricity in the air transport only free heat. Power consumption of ordinary electric water heater 1/4, ie when four kWh of electricity used. Easier - from environmental restrictions, can be installed anywhere in the indoor and outdoor, also without illumination requirements. More healthy - the biggest difference outes air heater than traditional tank water heater is an automatic cleaning function. The experimental test, outes air heater tank with a special material handling technology, greatly reducing the fouling rate in the tank, softening the water quality, care of your skin, and clean up the scale for you to remove the trouble. Faster - faster heating rate, stronger insulation efficiency, stable pressure and pressure to ensure that you have a hot water bath weather. More durable - quality professional compressor tank liner plus super insulation, plus ten years without fading shell is durable outes air heater, safe and trouble-free use of up to 12 years. Thermal Equipment Co., Ltd. in the crown of various types of air heat pump hot water unit products, we provide quality pre-sales consulting, QQ:? 1794787682, TEL:? 135.92649186 |
Admin>>>
You are the 22208 visitor
Copyright © GuangDong ICP No. 10089450, Thermal Equipment Co., Ltd. Henan crown All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 22208 visitor
Copyright © GuangDong ICP No. 10089450, Thermal Equipment Co., Ltd. Henan crown All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

